The e500 ventilator's Graphics Display Monitor (GDM) features a clear view of diagnostic information with touch-screen ease. Users gather critical feedback from easy-to-read waveforms, loops and measured and calculated numeric data. In addition to 24 hour trend data, the GDM provides an Event History Log that records the 600 most recent occurances of both alarm violations and changes to ventilator settings. The Wave/Loop Freeze with cursor function allows the user to gather the analysis of time, pressure, volume or flow at any point in the breath.

Back to main e500 page

e500 Ventilator Specifications
   
   



Graphics

 
  Waves: Pressure-time
Volume-time
Flow-time
Multi-waves
(all displayed on one screen)
  Loops: Volume Pressure
Flow volume
Multi-loops
(all displayed on one screen)
  Waves and Loops: Displays all waves and loops on one screen
   
Two Trend Screens Available
 
  VTE / time Ppeak/time
  E / time Pmean/time
  ƒtot / time Pbase/time
  %Leak / time ƒ/VTspont/time
   
Extended Functions Management
   
  Automatic Leak Compensation: On / Off
  Slope / Rise: 1 – 19
  Expiratory Threshold: 5 – 50 % of peak flow
  Event History Log: 600 most recent alarm violations and ventilator settings recorded
     
Parameters Monitored/Calculated
 
  Cstat ƒspont
  Cdyn effective ƒ/VTspont
  tE minimum tI
  RI I:E
  RE % Leak
  PEEPtot stat peakI
  Pplat peakE
  Ppeak I
  Pmean E
  Pbase E spont
  Ptrig VTI
  WOBim VTE
  ƒtot VTE% Variance
     
 
 
 
  Power Requirements
 
  GDM is electrical powered by a DC power source in the e500 ventilator.
  GDM only functions when connected to e500.
  Power consumption in 30 W at 14 VDC.
   
Dimensions
 
  Width: 12.6 in (32 cm)
  Depth: 2.5 in (6.4 cm)
  Height: 8.9 in (22.7 cm)
  Weight: 7.50 lbs. (3.4 kg)
   
Additional Details

  Patient Information: From the Set Up screen, patient weight and name (or ID number) can be entered.
  Display: 10.4 in. (26.4 cm) active matrix color LCD, 640 x 480 flat panel LCD
  Ventilator Communications: Serial port interface to e500 ventilator. Ventilator data is processed at 100 Hz and displayed real-time. Power and serial communication lines are included in one cable connection to ventilator.
  Printer Communications: Parallel port interface to HP DeskJet 895 Cxi color printer or equivalent.
 
 
 
Specifications subject to change without notice.