When critical care meets innovation, you get truly intuitive care
- you get the Newport e500 Ventilator. With its Intelligent Control
System for maximum patient/ventilator synchrony, easy-to-use control
panel, and a touch screen graphics display monitor; the e500 is
the patient-focused ventilator of the future.
|
New Software Upgrades include
new and modified specifications. This page will be updated
soon! Contact
Us for more details.
|
|
Designed for simplicity of use, the e500 offers direct access to all
ventilation controls along with other frequently used functions such as
Inspiratory and Expiratory Hold, 3 min Oxygen, Suction Disconnect and Preset
Vent Settings. The logical layout of the front panel and smart alarm systems
make ventilator setup and training quick and easy. And the self-calibrating,
integrated oxygen monitor with alarms, the panel lock, and an
internal battery all provide the smooth ventilator management necessary
to assure peace of mind.

Exclusive to the e500 ventilator, the e500 Graphics Display Monitor features
a clear view of diagnostic information with touch-screen ease. In addition
to 24 hour trend data, the GDM provides an Event History Log that records
the 600 most recent occurances of both alarm violations and changes to ventilator
settings. The Wave/Loop Freeze with Cursor function allows the user to gather
the analysis of time, pressure, volume or flow at any point in the breath.


 |
 |
 |
 |
 |
Intelligent Control System
FlexCycle Flexible Pressure Support Cycling Threshold,
Automatic Slope/Rise Adjustment, Automatic Leak Compensation,
Dual Control Breath Management (VTPC/VTPS).
 |
 |
Suction Disconnect
Press and hold Alarm Silence for one second to enable. Suspends
ventilation while delivering continuous flow after a planned
disconnect.
 |
 |
User Set Up Functions
Leak Test, Circuit Compliance Compensation (calculate and enable
breathing circuit compliance of flow/volume delivery), enable
90-second Slow Inflation, Altitude Compensation, Language Selection,
Violation Message Log.
 |
 |
Bias Flow
Ventilator-set bias flow flushes exhaled CO2 and
stabilizes temperature, humidity and baseline pressure in the
patient breathing circuit.
 |
 |
Non-invasive Ventilation
Compatible with mask ventilation for continuous or short term
use.
 |
 |
O2 Calibration
Automatic oxygen sensor calibration at software determined intervals.
 |
 |
Preset Vent Settings
Mode, Breath type and settings can be preset without affecting
current ventilator operation.
 |
|
 |
 |
| |
 |
|