Simple. Logical. Smart. The Breeze 150 provides everything you need in one compact, cost effective package. It has the versatility to let you choose pressure or volume ventilation for neonates, pediatrics or adults.


Back to main E150 page
View E150 Monitor Face
 
   


Controls/Settings

 
  Modes: Volume A/C
  A/C + Sigh
  SIMV
  SPONT
  Modes: Pressure SIMV A/C
    SPONT
  Power: On/Off
  FIO2 .21-1.00
  Flow 1 - 120 L/min
  Inspiratory Time: 0.1 - 3.0 sec
  I:E Ratio: 1:99 - 4:1
  Set Rate: 1 - 150 b/min
  Tidal Volume: .01 - 2.0 L
  PIP (PCV): 0 - 60 cmH2O
  PEEP/CPAP: 0 - 60 cmH2O
  Spontaneous Flow: 0 - 40+ L/min
  Trigger Level: -10 - +60 cmH2O
  Pneumatic Pressure Relief: 0 - 120 cmH2O
  Nebulizer: On/Off
  Sigh: 1.5 x Inspiratory Time Every 100 breaths
  Manual Breath: Operator controlled: volume or pressure breath
     
  Alarms
 
  Audible and Visual:  
  High Pressure: 10 - 120 cmH2O
  Low Pressure: 3 - 99 cmH2O
  Apena: 5 - 10 - 15 - 30 - 60 sec
  Low CPAP: Alarms after 4 seconds
  Low Battery: Approx. 15 minutes remaining operational time
  Audible Only: Gas supply source failure
Power failure
Power down
  Alarm Loudness: Adjustable 72 - 82 dBA
  Alarm Silence: 60 seconds
     
 
  Other Features
 
  Pressure Sensing: Proximal
  Preset: Displays control settings in SPONT mode
  Remote Alarm Outlet: RS-232 output
  Hour Meter: 0 - 99,999 hours
     
  Power Requirements
 
  A.C. Power: 100, 120, 220 or 240 VAC
± 10%, 47 - 63 Hz
45 watts maximum
  Battery Power: Internal Battery - 1 hour minimum
Recharge - 18 hours maximum
     
  Gas Requirements
 
  Air: 35 - 90 psi (50 ± 10 nominal)
  Oxygen: 35 - 90 psi (50 ± 10 nominal)
     
  Dimensions and Weight
 
  Height 10in (25cm)
  Width 13in (33cm)
  Depth 11in (28cm)
  Weight 30lbs (13.6kg)
  Ship Weight 64lbs (29kg)
     
  Outputs
 
  Analog 10 mV/cmH20
  Digital RS-232, 1200 baud
     
  Agency Requirements

 
    Meets requirements of CSA 22.2,
IEC 601-1 and IEC 601-1-2 EMC
EMC Directive 89/336/EEC
MDD Directive 93/42/EEC
Displays/Indicators:
 
  Set FIO2 Set Low Pressure Alarm Mean Pressure
  Flow Set High Pressure Alarm Baseline Pressure
  Spontaneous Flow Set Tidal Volume/Exp.Time Trigger Level
  Inspiratory Time I:E Ratio Battery in Use
  Set Rate Pressure Gauge Effort
  Total Rate Peak Pressure  
       